Weight shutter, fire shutter

Weight shutter, fire shutter

As a specific fire prevention device under the Building Standards Act (Enforcement Order Article 112, Paragraph 1), it is used in fire compartments, etc. 【Features】 ○ It can automatically close using heat and smoke detectors, and can also be manually operated for closure at any time. ○ There are five types of slat shapes: standard type and reversal type (Type B). ○ The opening width can accommodate up to a maximum of 15 meters. 【Specifications】 ○ Operation: 3-point push button switch ○ Manual operation: Handle type, chain type ○ Automatic closing device: Operates based on signals from heat and smoke detectors to lower the shutter. ○ Manual closing device: A device that allows the shutter to be closed manually in case of emergency. ○ Hazard prevention device: If an obstacle contacts the seat board while descending due to signals from heat and smoke detectors, the shutter stops to prevent pinching accidents. ● For other functions and details, please contact us.

  • shutter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Komata Shutter Manufacturing Co., Ltd. Company Profile

Responding accurately to the demands of the times, walking alongside the era... Omata will advance with the times.

Komata Shutter Industry Co., Ltd. was founded in the early Showa era and has dedicated over 80 years to the research and development of disaster prevention shutters. We have consistently challenged ourselves to stay ahead of the times with our unique know-how, and we take pride in having earned the reputation of "Technology of Komata" through the excellence of our products and the reliability of our installations. Moving forward, we aim to create products that are not only superior in quality and cost-effectiveness but also provide greater peace of mind by accurately understanding and responding to our customers' needs. We are committed to offering the essence of sincerity and conscience as a manufacturer, not only in specialized smoke and fire shutters but also in related building materials. 【Business Overview】 ■ Research and Development of Disaster Prevention Shutters *For more details, please refer to the PDF document or feel free to contact us.

  • shutter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Recommended regular inspection of shutters.

For daily safety and peace of mind, we recommend optimal maintenance based on the new inspection standards.

At Komata Shutter Industry Co., Ltd., we conduct regular inspections of shutters. It has become mandatory to inspect and report the operational status of fire doors and fire shutters installed in special buildings, etc. Therefore, building owners or managers must confirm and report that the operational status of fire doors and fire shutters ensures the safety of individuals while closed. Additionally, if regular inspections and daily maintenance are not adequately performed, there is a possibility that they may not function properly during a fire. Therefore, we recommend regular inspections by professionals. *For more details, please refer to the PDF materials or feel free to contact us.

  • shutter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Smoke and Fire Shutter Catalog

Non-combustible thermal insulation structure prevents smoke! Featuring smoke and fire shutters.

The "Smoke Prevention Shutter/Fire Prevention Shutter Catalog" is a product catalog from Omata Shutter Industry Co., Ltd., which conducts research and development on disaster prevention shutters. It features non-combustible "Smoke Prevention Shutters" that do not use any rubber in their smoke-blocking materials, as well as "Fire Prevention Shutters" with slat shapes. [Contents Included] ■ Smoke Prevention Shutter ■ Dimensions of Each Part ■ Fire Prevention Shutter (Slat Shape) ■ Guide Rail ■ Opening and Closing Mechanism *For more details, please refer to the PDF document or feel free to contact us.

  • shutter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Notice of Shutter Regular Inspection

The regular reporting system for fire prevention equipment has changed, and inspections and reports have become mandatory.

At Omata Shutter Industry Co., Ltd., we conduct regular inspections of shutters. As a measure to prevent accidents where fire doors, which are supposed to close automatically during a fire, do not operate properly, it has become necessary to conduct regular inspections by fire protection equipment inspectors through the introduction of new inspection standards and a review of the inspection targets. Inspections of fire protection equipment and fire extinguishing equipment as required by the Fire Service Act must both be carried out. If fire doors, fire shutters, and fire dampers that block smoke and flames are not adequately maintained through regular inspections, they may not function effectively during a fire. Regular inspections by fire protection equipment inspectors are necessary. 【Target Fire Protection Equipment】 ■ Fire doors ■ Fire shutters ■ Fire-rated cross screens ■ Deluge systems and other fire protection equipment that forms a water curtain *For more details, please refer to the PDF document or feel free to contact us.